Sprachauswahl

SUCHE

Suchbegriff:

Produkte

Technische Daten
Die wichtigsten Leistungsdaten auf einen Blick

InstrumentLuminance & Color Uniformity Analyzer UA-1000A
Photo detector1.4 million-pixel Monochrome Cooled CCD
Objective lensFocal length 3-level switching system
f=125mm (Wide angle)
f=25mm (Standard)
f=50mm (Telescopic)<BR> F2.8

Spectral sensitivity
characteristic
Approximate into the CIE 1931 color-matching function
* This fulfills JIS Z 8724-1997 router condition.

Number of
measurement points
1360x1024 (Binning1x1)
680x512 (Binning2x2)
340x256 (Binning4x4)
Luminance 0.005 to 100,000cd/m²
Luminance linearity±3% ※standard sources A, Luminance 0.005 to 100,000cd/m²,
evaluated on the center of the CCD
Chromaticity accuracy±0.005 ※standard sources A, Luminance 0.005 to 100,000cd/m²,
evaluated on the center of the CCD
In-plane
unevenness
uniformity

Luminance±2%※Center of the CCD, standard sources A, 30 cd/m²

Chromaticity±0.003
Repeat
Characteristic


Luminance0.5% (2σ)※Standard Measurement Mode

Chromaticity0.0020 (0.01cd/m² or more)
0.0025 (Less than 0.01cd/m²)
Luminance0.65% (2σ, 0.1cd/m² or more)
0.75% (2σ, Less than 0.1cd/m²)

※High-Speed Measurement Mode
Chromaticity0.0040
Measurement Time

Fastest about 5sec
(standard sources A, Binning 4x4, High-Speed Measurement Mode)

StabilityLuminance1% (standard sources A, evaluated on the center of the CCD)
RepeatabilityLuminance2% (standard sources A, evaluated on the center of the CCD)
Temperature characteristicLuminance±3% (At 15 to 30℃ ※reference: 25℃)
Humidity Luminance±3% (At 70%R.H.)
Calibration standard

TOPCON calibration standard
(standard sources A, 23℃±3℃
User calibration standard Switchable)
Interface

USB2.0
Power supply

100 to 240V AC (50/60Hz)
Power consumption

Photo detector: 100V, 120VA
(Excluding the computer)
Operating conditions

Temperature15℃ to 30℃
Humidity70%R.H. and below (No condensation)
Storage condition

Temperature-5℃ to 50℃
Humidity70%R.H. and below (No condensation)
Outer dimensions

294(L)x210(W)x244(H)mm
Weight

Only Detector: 6.9Kg
With CloseupLens1: 9.6Kg
With CloseupLens2: 10.6Kg


(It is possible to perform the following measurement depending on the display mode.)

Measurement distance (mm; metal, form)
10001250150017502000
Wide angle (inch)30.537.644.651.658.6
Vertical(mm)/
Horizontal(mm)
619.8/
464.8
619.8/
464.8
906.3/
679.7
1048.5/
786.4
1190.8/
893.1
Standard16.520.0023.627.130.6
Vertical(mm)/
Horizontal(mm)
335.3/
251.5
406.4/
304.8
479.6/
359.7
550.7/
413.0
621.8/
466.3
Telescopic
(inch)
9.411.212.914.716.4
Vertical(mm)/
Horizontal(mm)
191.0/
143.3
227.6/
170.7
262.1/
196.6
298.7/
224.0
333.2/
249.9

*Measuring distance is from top of objective lens unit to object.
*The value in this table are design reference values and may differ somewhat from the actual diameter.


AL-UA1AL-UA2
Measurement distance (mm; metal, form)55378.1
Wide angle (inch)16.05.4
Vertical(mm)/Horizontal(mm)325.1/243.1110.5/82.9
Standard (inch)8.02.7
Vertical(mm)/
Horizontal(mm)
162.6/121.955.3/41.5
Telescopic(inch)4.01.4
Vertical(mm)/Horizontal(mm)81.3/61.027.6/20.7

*Measuring distance is from top of objective lens unit to object.
*The value in this table are design reference values and may differ somewhat from the actual diameter.